Iron LR – low range iron measurement for photometers, 10 tablets
Iron LR by Water-i.d. for low range iron measurement. Pack: 1 blister of 10 tablets. LR means Low Range. The stated range applies specifically to the PoolLab 2.0 method.
Suitable for PoolLab 2.0 and other photometers whose manufacturer specifies this exact reagent for the selected method.
Iron LR: low range iron measurement
Iron using the Iron LR photometric method. The PoolLab 2.0 method covers 0–1 mg/l Fe. Water-i.d. analytical reagents are used to prepare a water sample for measurement, not for treating water directly in the pool.
What is included?
One blister containing 10 Iron LR tablets. The price and order quantity refer to this retail pack, rather than a full wholesale box. The photometer and any additional reagents are sold separately.
Required reagents
LR means Low Range. The stated range applies specifically to the PoolLab 2.0 method. A multi-reagent method may require several different products; purchasing this pack alone does not necessarily provide a complete test kit.
Short measurement guide
Select Iron LR, prepare the sample and perform ZERO. Dissolve the reagent and follow the instrument countdown.
This is a brief overview. Use the exact sample volume, reagent dose, ZERO procedure, filtration requirements, reaction times and limitations specified by the instrument and the current manufacturer manual. Ten tablets do not necessarily provide ten complete multi-parameter tests.
Photometer compatibility
Verified use is stated for the corresponding PoolLab 2.0 method. The reagent may also be used in another photometer whose manufacturer specifies this exact reagent and dose for that method. Matching the name of the measured parameter alone does not establish compatibility. Check the sample volume, reagent sequence, reaction time and instrument calibration in the manual for your model. RAPID tablets for visual pool testers must not be assumed suitable for photometers. Measurement ranges stated for PoolLab 2.0 do not automatically apply to another device.
PoolLab 2.0 manufacturer method overview
Storage and handling
Keep in the original sealed blister as directed on the packaging. Protect from moisture, check the expiry date of the actual batch, and open only immediately before testing. Follow the manufacturer packaging and safety data sheet. Avoid touching tablets with your fingers.
The photograph is illustrative and may show a larger manufacturer pack or several views of a blister. The supplied quantity is stated in the product title and description. Other reagents shown are not included.