Nitrate No. 1 for digital photometers – 10 sachets
Nitrate No. 1 by Water-i.d. for nitrate testing with a compatible digital photometer. The sales unit contains 10 sachets. Use with the other reagents specified by the method; this reagent alone is not a complete test. See the product description for PoolLab 2.0 instructions and required equipment. For water analysis only.
Nitrate No. 1: reagent for nitrate analysis
Nitrate No. 1 by Water-i.d. is a powder reagent for photometric nitrate measurement. Replace the specific reagent without buying a new testing instrument. Reliable results require the correct program, sample preparation and reagent combination.
What is included
10 sachets of Nitrate No. 1. The price and order quantity refer to this sales unit, not to the manufacturer’s wholesale box.
Other required reagents / equipment: Nitrate No. 2. Other reagents and the photometer are not included.
| Parameter | Value |
|---|---|
| Manufacturer | Water-i.d. |
| Form | Powder in individual sachets |
| Sales unit | 10 sachets |
| PoolLab 2.0 method | NTRA |
| PoolLab 2.0 range | 1–50 mg/l NO₃⁻ |
| Other reagents / equipment | Nitrate No. 2 |
Quick measurement instructions – PoolLab 2.0
- Measure 10 ml of sample water into a clean chamber. Close the cover and perform ZERO without reagents.
- Select Nitrate (NTRA); on PoolLab 2.0, test on its own in the middle chamber T2. Empty the measuring chamber after ZERO.
- Measure 20 ml of sample into a separate clean, sealable container. Add 1 Nitrate No. 1 sachet, followed by 1 Nitrate No. 2 sachet.
- Close the container, shake for 15 seconds and allow a reaction time of 10 minutes.
- As instructed in the manual, transfer 10 ml of the prepared sample into the measuring chamber and complete the NTRA test.
Do not skip the instrument countdown. Use clean equipment and rinse the chamber and stirring rod thoroughly after testing. Check exact conditions, pretreatment and possible interferences in the manufacturer’s instructions.
Digital photometer compatibility
The stated procedure and measuring range apply to the corresponding PoolLab 2.0 method. For another photometer, use this reagent only if its manufacturer specifies this exact reagent and procedure. A matching parameter name alone does not establish compatibility. Do not confuse No. 1 with No. 2 or LR (low range) with HR (high range).
Storage and handling
Keep in the original tightly closed packaging as directed by the manufacturer. Prevent contamination, check the expiry date and follow the label and safety data sheet for the supplied batch. For analysis of a water sample only; do not add directly to pool water. Keep out of reach of children.