Roller head for VA DOS Basic / Exact pump
Three-roller assembly · RIC0152561 · Diagram position 4
The roller head compresses the peristaltic tube to move the dosed liquid. This is the separate replacement head shown as position 4.
Catalogue code: RIC0152561
Advice from our pool specialist
Compare the drive coupling and head shape before replacement. The tube and motor are not automatically included.
Roller head for VA DOS Basic / Exact pump
Three-roller assembly · RIC0152561
The roller head compresses the peristaltic tube to move the dosed liquid. This is the separate replacement head shown as position 4.
When to choose this part
A separate head may be appropriate when the rollers are worn or mechanically damaged. Inspect the peristaltic tube and cleanliness of the mechanism at the same time.
Compatibility and version
Compare the drive coupling and head shape before replacement. The tube and motor are not automatically included.
The name Basic / Exact alone does not establish compatibility. Compare the original part code, connections and mounting with the station label and documentation.
Identification
| Catalogue code | RIC0152561 |
|---|---|
| Diagram position | 4 |
| Product type | Service spare part |
Installation and final check
Switch off and isolate the station before servicing. Electrical work must be carried out by a qualified technician. When opening pipework, stop circulation and release pressure. After replacement, check secure mounting, connections and operation according to the station manual.
What you are ordering
This is the spare part named above, not the complete VA DOS station. Images taken from the original parts diagram are identification aids, not photographs of package contents. Other parts visible in the diagram are not automatically included.
Need help identifying the part? Send the station label and a photo of the original component to info@chemie-bazen.cz.
Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!