Zodiac eXO housing seal
Diagram position: 11
Shaped seal for the control-unit housing. Compare the complete groove and original seal; this is not the round O-ring used on the electrolytic cell.
Catalogue reference: WR0823600.
Advice from a pool technician
Select primarily by catalogue reference and the original version. The original eXO iQ and the newer eXO iQ R can have different electronics and connectors. Appearance alone does not establish compatibility.
Zodiac eXO housing seal
Shaped seal for the control-unit housing. Compare the complete groove and original seal; this is not the round O-ring used on the electrolytic cell.
Purpose of the part
This is a separate service component for a specific part of the assembly. Distinguish between the electrode, empty cell housing, connection parts and electrical components when ordering; the complete assembly drawing does not define this item’s contents.
Identification and selection
Diagram position: 11
Catalogue reference: WR0823600
Replacement and checks
Before opening the water circuit, switch off the equipment, stop circulation and release pressure as instructed. Clean mating surfaces and inspect seals. Avoid overloading plastic threads during reassembly and check for leaks after restarting.
If unsure about the version, send photos of the original component and equipment label to info@chemie-bazen.cz.
Position in the assembly
The blue arrow identifies the component in the original drawing. The unmarked original is retained in the gallery.

Product rating
Be the first who will post an article to this item!
Discussion
Be the first who will post an article to this item!