Redox Calibration Solution 468 mV - universal (Vagnerpool, Aseko, Astralpool, etc.)
ORP 468 mV calibration solution. Use only with an instrument that accepts this reference point; the calibration value and procedure must match its settings. Pack 50 ml.
Pool specialist opinion
- Redox 468 mV reference value
- For calibration of a suitable instrument
- A practical part of measuring-equipment care
Select the Redox 468 mV solution according to your device’s calibration procedure. Rinse the probe between solutions and gently absorb remaining drops by touching with clean toilet tissue, without rubbing the sensitive part. This reduces carry-over of the preceding solution and excess rinse water.
The Poolservis team
A reference solution for more dependable measurement
Calibration solution is an important part of the equipment used to maintain a suitable probe, measuring instrument or dosing controller. It allows a check and calibration against a known reference value using the procedure required by the particular device. Keeping a suitable solution available means you can carry out maintenance or verify a reading when needed, rather than considering calibration only after you have lost confidence in the instrument’s display.
Choose the correct reference value
Before ordering, compare the value in the product name with the requirements of your instrument. pH and Redox solutions have different purposes, and individual reference values cannot be interchanged at will. Some procedures require more than one reference point; the required number and values are set by the device documentation. A similar brand name or probe connector does not by itself establish that two devices use the same calibration procedure.
Start with a clean portion of solution
Prepare a clean vessel and a fresh portion of the solution needed for the procedure. Do not return used solution to the storage bottle, because remnants of the previous solution or contamination from the probe can enter it. Work carefully between reference solutions and allow the reading process to follow the device instructions. Gently absorb remaining drops without rubbing the sensitive part of the probe, as described in the specialist tip. Keep the main bottle protected during the process.
Calibration as part of regular probe care
Solution alone cannot repair a damaged or poorly maintained probe. If a result is unsatisfactory, check the solution choice, probe condition and instrument procedure. Follow the device documentation and packaging information for calibration conditions, any temperature dependence and the required stabilisation. Close the bottle after taking a portion and store it according to the instructions for the particular solution. Clean handling and the right reference value matter more to a meaningful calibration than finishing the procedure quickly.
Use a fresh portion of ORP 468 mV solution in a clean container for calibration. Never return solution contaminated by an immersed probe to the stock bottle. Keep closed and observe the expiry date and reference conditions on the pack.
Additional parameters
| Category: | Automatic chemical dosing |
|---|---|
| Weight: | 0.1 kg |
| Brand: | Vagnerpool |
| What it measures / testing application: | Redox (ORP) |
| ? Product type: | Calibration solution |