Tablet tester PoolTest PT400 (Ph/Cu/Zn)
The PoolTest PT400 tablet tester from Water I.D. reliably measures pH, free copper, and zinc levels in pool water. The package includes 20 tablets each of Phenol Red, Copper/Zinc LR, EDTA, and Dechlor, giving you everything you need for quick, accurate, and battery-free testing of three key parameters.
Instructions and description – PoolTest PT400 tablet tester
Pool specialist opinion
- Measures pH, copper and zinc with one tester
- Precise 8-colour scale
- Includes 20 tests for each parameter
- Easy tablet crushing with the supplied stirring rod
- Replacement tablets must be purchased when the originals run out
- Dilute the sample if Cu > 0.9 mg/l
“The PT400 combines three key parameters in one compact tester. The differential method lets you determine zinc without complicated calculations, while the precise colour scale minimises visual reading errors.”
The Poolservis team
Practical pH, copper and zinc tester
The PoolTest PT400 tablet tester from German brand Water I.D. provides reliable pH measurements (6.8–8.2 pH) and free copper measurements (0–0.9 mg/l), while a simple calculation also gives the zinc concentration. Three chambers allow parallel or sequential testing, saving time during regular pool maintenance.
Everything in one pack
The box includes the tester, 20 Phenol Red tablets, 20 tablets of Copper/Zinc LR, 20 tablets of Phenol Red Rapid, 20 tablets of EDTA, 20 tablets of Dechlor and a plastic rod. Remove the lid, collect a water sample, mix in the crushed tablet and read the colour after one minute.
Easy use without electricity
Unlike electronic pH meters, there are no batteries or calibration to worry about. The PT400 uses visual colour comparison, with a high-contrast scale that is easy to read in daylight.
Differential method for zinc
Determine zinc by subtracting two readings: first Cu + Zn, then Cu alone after adding EDTA and Phenol Red Rapid. The difference gives the zinc concentration without an expensive photometer.
How to test correctly
Take the sample 20 cm below the surface and away from return jets. If free chlorine exceeds 1 mg/l, use a Dechlor tablet first. Rinse after every measurement so reagent residues do not affect subsequent tests.
Detailed instructions for the Water I.D. PT400 tester
1 ) Prepare everything needed
| Item | Purpose |
|---|---|
| PT400 tester with three chambers | Left = pH, centre = Cu + Zn, right = Cu |
| Tablets | Phenol Red, Phenol Red Rapid, Copper/Zinc LR, EDTA, Dechlor |
| Plastic crushing rod | Crushing and mixing tablets |
| Watch / phone | Timing 1 minute intervals |
| Water sample | Collect from approximately 20 cm deep |
Remove the tester lid to access the chambers.
2 ) Measuring pH
- Fill the left chamber to the mark.
- Add 1 Phenol Red tablet and stir until dissolved.
- The colour stabilises within 10 s. Hold the tester at eye level and compare with the scale (6.8–8.2).
3 ) Measuring copper and zinc (differential method)
| Step | Centre chamber (Cu + Zn) |
Right chamber (Cu) |
|---|---|---|
| Dechlor(if free Cl > 1 mg/l) | 1 tablet of Dechlor | – |
| Adding the Cu + Zn reagent | 1 tablet of Copper/Zinc LR, stir | – |
| Timer → 1 min | Read the colour as A (Cu + Zn) | – |
| Masking zinc | 1 tablet of EDTA + 1 tablet of Phenol Red Rapid, stir | Fill with a fresh sample and repeat the steps above |
| Timer → 1 min | – | Read the colour as B (Cu) |
| Calculating Zn | Zn (mg/l) = A − B | |
4 ) Recommended pool target values
| Parameter | Ideal range |
|---|---|
| pH | 7.2–7.6 |
| Free copper (Cu) | ≤ 1.3 mg/l (recommended < 0.3 mg/l) |
| Zinc (Zn) | < 0.5 mg/l |
5 ) Tips for accurate results
- Take the sample 20 cm below the surface, away from return jets.
- Wash the chambers thoroughly after each test.
- Store tablets in a cool, dry place; open blisters immediately before use.
- Always use Dechlor when chlorine levels are high.
- If the colour has not changed after 1 minute, wait no more than another 30 s.
6 ) Safety
- Tablets must not be swallowed. Keep out of reach of children!
- Handle with dry hands to prevent premature dissolution.
- Used solutions may be poured down the drain; they do not contain hazardous concentrations of metals.
Additional parameters
| Category: | Tablets Test Kits |
|---|---|
| Weight: | 0.02 kg |
| Brand: | Water I.D. |
Product rating
Be the first who will post an article to this item!